8. Instructions

PNEG-4030 40 Series 27' and 30' Diameter Bins

75

Wire Grill Guard Roof Vent Assembly and Installation Instructions

The following instructions are for assembling and installing the wire grill guard roof vent. Before beginning
assembly, check the packing list to ensure all components have been received. The unit is easiest
assembled in the upside down position as shown in

Figure 8F

. Locate the roof vent as shown in

Figure 8J on Page 77

.

Assembly

1. Turn one roof vent housing (MIS-6778) upside down.

(See Figure 8F.)

2. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the hole in the side of the roof vent.

Place jamb nut onto the bolt and tighten.

(See Figure 8F.)

3. Slide one eyelet of grill guard onto the 5/16" bin bolt.

4. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the other side of the roof vent, through

jamb nut and other eyelet of grill guard. Tighten nut against vent housing side.

5. Apply a bead of tube caulking around the three (3) housing sides of the roof vent where it meets the

hold-down angle.

6. Place hold-down angle (MIS-4404) on the assembled roof vent. The wide end of the hold-down angle

must face the vent discharge. Once aligned, screw nine (9) #10 self-drilling (S-280) screws through
the roof housing and into the hold-down angle.

(See Figure 8G on Page 76.)

Figure 8F

Ref #

Part #

Description

A

MIS-6776

Grill Guard

B

MIS-6778

Vent Housing Assembly

C

5/16" x 1-1/4" Nut and Bolt

Advertising