Installation, Chapter 5, Boot and transfer plate installation – Grain Systems Bin Accessories PNEG-914 User Manual

Page 15

Advertising
background image

PNEG-914 Flex-Flo

15

5. Installation

Boot and Transfer Plate Installation

NOTE: Installation of the boot is the same whether the tank has the standard collar or the Sure-Flo Feed

Flow Control.

Slide the boot as far as possible into the tank collar or the Sure-Flo Feed Flow Control opening.

(See Figure 5A.)

Align the boot with the Flex-Flo System that will be installed. Using the holes in the collars

for guides, drill eight (8) 11/32" holes into the boot rim.

(See Figure 5B.)

Mount the boot to the collar with the hardware provided. Bolt the transfer plate and unloader braces to the
boot as shown.

See Figure 5C

for proper usage and assembly direction of hardware for mounting the boot

and the transfer plate. All connections should be tightened until they are “snug”.

Figure 5A

Figure 5B

Figure 5C

Improper installation methods of the hardware may cause permanent damage and
possible breakage of the boot.

CAUTION