5. Installation

PNEG-914 Flex-Flo

27

Belt Drive Power/Control Unit

1. Bolt the tube anchor to the control unit body with a flat washer on each of the four (4) 5/16'' x 3/4''

bolts. (

See Figure 5Q on Page 26

for more details.)

2. Insert the driver shaft through the bearing assembly. The bearing mounting plate should be mounted

in between. Tighten the set screw on the bearing down to the shaft.

3. Bolt the two (2) mounting brackets together with the four (4) bolts and washers provided.

4. Attach the motor support assembly to the control unit with the four (4) bolts already in the mounting

bracket and belt guard. Secure with the four (4) lock washers and hex nuts provided. If necessary,
motor orientation can be reversed by rotating the motor mount 180°.

5. Slide and clamp a tube coupler on the anchor.

Figure 5T Belt Drive/Power Unit

6. Mount the motor onto the motor mount base with four (4) bolts and washers.

7. Mount the belt pulleys. The two (2) pulleys must be positioned in line with each other to prevent from

binding the belt.

8. Install the belt.

9. Adjust the belt tension by extending and retracing the two (2) mounting brackets. Resecure the bolts

after adjustment.

10. Install belt guard cover.

11. Attach the power/control unit to the Flex-Flo tubing.

12. Suspend the power/control unit firmly from the ceiling using the chains provided.

13. The control unit and the power unit must be wired as shown in the

Wiring Diagrams on Pages 55-62

.

14. Install the auger.

Advertising