5. Installation
18
PNEG-914 Flex-Flo
Feed Tank Collar
The standard bulk feed tank is supplied with a 16'' (40.64 cm) hopper opening. If needed, 22'' (55.88 cm)
hopper openings are also available. Consult the dealer for specific ordering instructions.
Restrictor Adjustment
The restrictor may be adjusted to allow more feed flow. Do not modify the restrictor until the system is
completely operational and the auger has been polished by running feed through the system.
Instructions:
1. Remove the restrictor tube from the unloader.
2. Cut 1" (2.5 cm) from the restrictor.
3. Install the restrictor and the bearing assembly into the unloader.
4. Test the feed flow.
5. If the desired feed flow rate is not attained, repeat the above procedure until the desired rate
is reached.
Figure 5G Restrictor Adjustment