Chapter 8: Accessories

5. Remove the roof exhauster mounting plate (F), to make the necessary cut along the mark or scribe

(I).

Figure 8-7 Using the roof exhauster flashing and mounting plate as a template

I

Marked or scribed hole to be cut

6. After the roof panels are cut appropriately, install the roof panels onto the roof in the desired location.

Assembly of Roof Exhauster

Assembly of the roof exhauster is done prior to installing onto the roof.

1. Apply a strip of tube caulk (C) along the mating surface of the roof exhauster hood (B) and the

exhauster mounting plate (E).

2. Install the roof exhauster hood (B) to the exhauster mounting plate (E), and align all the holes.

3. Install hex head bolts (A) and flange nuts (D), securing the roof exhauster hood (B) to the exhauster

mounting plate (E).