3. Specifications

Modular Tower Dryer Specifications

Models

TM-1008

TM-1010

TM-1012

TM-1015

Blower Size

43" Axial

43" Axial

43" Axial

48" Axial

Blower RPM

1775

1775

1775

1775

Blower HP

40

50

60

75

Metering HP

1

1

1

1

Drying CFM

38000

45000

52000

66000

Cooling CFM

19500

22500

26000

33000

Burner Capacity (mBtu)

2

8.2

9.7

11.2

14.3

Average Heat Use (mBtu)

5.1

6.1

7.0

8.9

Grain Column

12-3/4"

12-3/4"

12-3/4"

12-3/4"

Tower Diameter

1

10'-7"

10'-7"

10'-7"

10'-7"

Overall Height

42'-1"

48'-11"

55'-9"

62'-7"

Wet Holding (BU)

260

260

260

260

Maximum Heat Holding (BU)

552

726

900

1074

Minimum Heat Holding (BU)

450

624

798

972

Maximum Cool Holding (BU)

246

246

289

289

Minimum Cool Holding (BU)

144

144

187

187

Dryer Holding (BU)

1049

1223

1397

1571

Outside Catwalks

1

2

3

3

BPH (20%-15%) Maximum Cooling

800

1000

1200

1500

BPH (25%-15%) Maximum Cooling

480

600

720

900

BPH (20%-15%) Minimum Cooling*

900

1125

1350

1690

BPH (25%-15%) Minimum Cooling*

540

675

810

1010

¹ Dimensions exclude outside catwalk.

² Capacities listed are wet bushels/tonnes, shelled corn at listed moisture content and are
estimates based on drying principles, field results and computer simulation. Variance may
occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity),
excessive fines, adverse weather conditions, etc.

* Minimum cooling capacities with cooling floor set in the lower position and assumes utilization
of cooling in bin (dryeration).