SEREIS ONE HEATER

1. Mark location on transition one

(1) foot up from the bottom

(entrance collar) and centered

in the transition.

2. Drill or knock out 7/8" diameter

hole on marked location.

3. Install transition hi-limit using

supplied self drilling screws.

TRANSITION HI-LIMIT INSTALLATION

Figure 3: The transition connecting the heater to the bin with the plenum

thermostat in place.

PLENUM THERMOSTAT

MOUNTING

The plenum thermostat is the 4 x 4 white box with knob

that is preconnected to heater when heater is ordered

with thermostat.

1. 24" to the right side of the transition, drill one

3

/

8

" hole

(high temp) or 1

1

/

2

" hole (low temp) in the center of

the plenum in a valley (4.00" corrugation) or hill (2.66"

corrugation) on bin sidewall.

2. Insert the probe through the hole.

3. Position the housing so that the tabs are vertical, and

the cord exits the housing horizontally.

Plenum thermostat mounting on bin wall.

5. Caulk between the housing and the sidewall to seal.

4. Use 4 self drilling screws to mount the housing to the bin

sidewall.

HEATER INSTALLATION