Second heater installation, Sereis one heater – Grain Systems PNEG-583 User Manual

Page 20

Advertising
background image

20

SEREIS ONE HEATER

FOR UNITS USING

HF-7318 CONTROL BOARD

Second heater control is available with the HF-7318 heater

control board. For standard units no extra parts are re-

quired. For HI-LO units (1) TD-100282 relay must be

installed. INSTALLATION SHOULD BE MADE BY

A QUALIFIED ELECTRICIAN. When points are called

out in instructions they are in reference to points on draw-

ing below text.

INSTALLATION FOR STANDARD UNITS

1. Run (2) wires from main heater (heater that thermo

stat is connected to) to second heater.

2. Connect 2 wires to terminals 23 and 24 (points B and

A) of second heater control terminal strip in main

heater.

INSTALLATION FOR

HI-LO UNITS

1. Plug (1) TD-100282 relay into empty socket on HF-

7100 control board in main heater.

2. Run (4) wires from main heater (heater that thermo

stat is connected to) to second heater.

3. Connect 2 of the wires to terminal 23 and 24 (points

B and A) of second heater control terminal strip in

main heater.

Figure 4: The HF-7318 control board.

3. Connect other end of these wires to terminals 14 and

15 (points F and E) on lower left hand corner of HF-

7318 board in second heater.

4. Connect other end of these wires to terminals 14 and

15 (points F and E) on lower left hand corner of HF-

7318 board in second heater.

5. Connect other 2 wires to terminal 21 and 22 (points

D and C) of second heater control terminal strip in

main heater.

6. Connect other end of these wires to terminals 12 and

13 (points H and G) on lower left hand corner of HF-

7318 board in second heater.

SECOND HEATER INSTALLATION

Advertising