Heater installation, Sereis one heater fuel connection – Grain Systems PNEG-583 User Manual

Page 7

Advertising
background image

7

SEREIS ONE HEATER

FUEL CONNECTION

Important! Do not use propane tanks which have previously

been used for ammonia unless they have been purged ac-

cording to procedures of the National L. P. Association.

Be sure fuel supply system complies with all local codes

for L. P. gas installations.

HEATER INSTALLATION

LIQUID PROPANE

MODELS

3. After installation is complete check all connections

for leaks with liquid detergent or comparable. Wear

rubber gloves and

eye protection. Avoid contact

with liquid propane. DO NOT USE FLAME FOR

LEAK TESTING.

PROPANE VAPOR MODELS

1. Propane vapor models are designed to run directly

off of supply tank or from a separate external vapor-

1izer.

1. LP models are designed to run on liquid propane, with

liquid draw from the propane tank.Avoid using pro-

pane supply tanks that have been used for vapor

draw for long periods of time. When using liquid draw

systems any moisture that may be present in tank or

lines may freeze when system is used in cold weather.

To avoid this, the usual precaution is to purge the

system with methanol.

2. Run proper size line (see specifications) to liquid pipe

train on heater. Have a qualified gas service man

inspect installation to be sure that everything is in-

stalled according to local codes and ordinances.

2. Run proper size line (see specifications) to pipe train

on heater. Have a qualified gas service person in

spect installation to be sure everything iinstalled ac-

cording to local codes and ordinances.

3. After installation is complete check all connections

for leaks. DO NOT USE FLAME FOR LEAK

TESTING. (see above for other precautions.)

NATURAL GAS MODELS

1. Natural gas models are similar to vapor models, but

have a larger orifice to accommodate lower pres

sure sometimes found with natural gas.

2. Run proper size line (see specifications) to pipe train

on heater. Have a qualified gas service

man inspect installation to be sure everything is in

stalled according to local codes and ordinances.

3. After installation is complete check all connections

for leaks. DO NOT USE FLAME FOR LEAK

TESTING. (See above for other precautions.)

Advertising