Operating procedure, Sereis one heater – Grain Systems PNEG-583 User Manual

Page 13

Advertising
background image

13

SEREIS ONE HEATER

OPERATING PROCEDURE

STANDARD HEATER

OPERATION

1. Thermostat must be wired into heater control box for

heater to operate.

2. Open all manual shut-off valves to heater unit.

3. Start fan. This will supply power to heater.

4. Turn thermostat dial to its highest setting.

5. Turn toggle switch on.

6. Heater should now be lit. If not check to see that all

gas is on.

7. Set thermostat to desired setting (see deluxe thermo-

stat manual for adjusting deluxe thermostat control).

8. Gas pressure should be adjusted so burner is on 75

percent of the time.

HI-LO HEATER

OPERATION

1. Thermostat must be wired into heater control box for

heater to operate.

2. Open all manual shut-off valves to heater unit.

3. Start fan. This will supply power to heater.

4. Turn thermostat dial to its highest setting.

5. Turn toggle switch on.

8. Open low-fire ball valve all the way.

9. Turn thermostat dial back slowly until heater cycles

to low flame.

10. Adjust ball valve so that low-flame pressure is at

desired setting.

11. Turn thermostat dial to desired setting and wait for

bin plenum to come up to temperature. Heater should

cycle to low flame after a few minutes. If heater

does not cycle to low flame increase hi-flame gas

pressure.

12. Low-flame should be adjusted so that temperature

drops slowly until burner goes back to high flame.

13. Watch as burner goes through a few cycles, to be

sure that it is operating properly.

9. Watch as burner goes through a few cycles, to be

sure that it is operating properly.

6. After 20 seconds both red lights should light up indi

cating power to the control circuit.

7. Heater should now be lit. If not check to see that all

gas is on.