42
12" & 16" Series II Sweep PNEG-720-G2
Assembly
S. Mount the control panel outside the bin near the door.
The plugs are different for each cord and MUST be assembled correctly. This is
done so the cords can not be plugged into the control panel incorrectly.
The control panel MUST be mounted OUTSIDE the bin near the door. The
foot switch has to be plugged into the control panel and depressed before
the sweep is operational. It has a 10' cord so the sweep can only be moni-
tored from OUTSIDE the bin.
15. ELECTRICAL ASSEMBLY (CONT.)
R. Assemble the cord plugs to the other end of each cord. The 14 AWG/4 wire cord requires the
"HBL2431SW" plug. The 10 AWG/4 and 8 AWG/4 wire cord requires the "CS8165C" plug. The
14 AWG/3 wire cord requires the "HBL2311SW" plug.
1/2" to 5/8" cord
connector body
rubber
grommet
plastic
ring
1/2" to 5/8" cord
connector cap
14 AWG/4 wire cord
(HBL2431SW)
1" to 3/4"
reducer
bushing
14 AWG/3 wire cord
(CS8165C)
5/8" to 3/4" cord connector
for: 10 AWG/4 wire cord
(HBL2431SW)
FIG. 15-R
3/4" to 7/8" cord connector
for: 8 AWG/4 wire cord
(HBL2431SW)