18. Voltage Reference

ATmega4HVD/8HVD features an internal bandgap reference. This reference is an input refer-
ence to the ADC, the Battery Protection module, the Voltage Regulator, and the Black-out
Detection. The bandgap reference voltage cannot be observed directly at any output in normal
operation. During factory testing, the bandgap reference will be calibrated. This final calibra-
tion cannot be changed by software. See

”System and Reset Characteristics” on page 144

for

details.