Qtp 2x, Fq 2x – OSRAM QUICKTRONIC-M ECG for circular FL 16 mm User Manual

Page 17

Advertising
background image

16

Replace both lamps, take out the lamp replaced first and refit it. Provided
lamp and ECG are o.k. both lamps should then light.

2.5.1 Lamp ignition for QTi

Lamp start

Preheat

Ignition time

< 1 second

Max. number of switching cycles > 100,000 cycles

2.5.2 Lamp ignition for QT

to operate T5-
fluorescent lamps

QT-FH MULTI, QT-FQ, QT…F/CW

Lamp start

Preheat

Ignition time

< 0.5 second

Max. number of switching cycles > 100,000 cycles

2.5.3 Off- Time for

Optimum Preheat
Start

All QUICKTRONIC to operate T5/

16 mm- fluorescent lamps

FH

®

…HE, FQ

®

…HO and FC start the lamps at any time with optimum

preheat start even after a turn-off followed by an immediate lamp
restart. OSRAM QUICKTRONIC ignite the lamp always with optimum
preheating of the electrodes. A particular off-time with regards to
lamp life is not necessary.

2.6 Behaviour in Response

to Lamp Defects

What do we mean by lamp defect or end-of-lamp life?

In most cases, it is not possible to see from outside which lampholders are
assigned to which ECG-terminals, so if you insert lamps and they fail to
start automatically you should take out the first lamp again and refit it. Both
lamps should then light.


Lamp replacement of 2- and multilamp luminaires proceed as follows:
Insert the lamps. If at 2- or multilamp luminaires lamp ignition doesn’t work
automatically, take out the lamp replaced first and refit it. Reignition of both
lamps works automatically.

2.6.1 One-Lamp

Operation

with Multi-Lamp ECG

What are the requirements?













Parallel

Circuitry Series

Circuitry

U

U

Start

U

U

Start

QTP 2x...

I

L

I

L

I

L

I

L

QT

-

FQ 2x...

I

L

U

Zünd

I

L

QT

-

FQ 2x...

I

L

I

L

U

Start

I

L

I

L

Advertising