OSRAM QUICKTRONIC-M ECG for circular FL 16 mm User Manual

Page 63

Advertising
background image

62

In summary, we can say that the ECG should be installed in such a way
that spray, water drops and condensation cannot enter the ECG and that
moisture and condenses inside the ECG can run out.
An ECG can withstand condensation for short periods but long-term
exposure to moisture should be avoided. The ECG must be operated for at
least 30 minutes per day so that condensation inside the ECG can
evaporate.

The luminaire casing should not be hermetically sealed. Instead, it should
be ventilated so that the condensate that forms during the cool-down period
as a result of the change in temperature (a luminaire is switched on, say, at
–10 °C, warms up during operation to +30 °C and then cools down again to
–10 °C after it has been switched off) is not trapped inside the unit and can
evaporate safely.

6.1.2 OUTKIT

Technical Data

OUT KIT Short

OUT KIT Long

Voltage Range

198 V to 264 V

198 V to 264 V

Temperature Range

-25 °C to 50 °C

-25 °C to 50 °C

Lenth

485 mm

550 mm

Height

38 mm

38 mm

Distance mouting whole
a

452 mm

517 mm

Standard pack [pcs.]

20 20

OUT KIT Short for ECG with l = 360 mm
OUT KIT Long for ECG with l = 423 mm
Permitted cable diameter for use of standard cables:

-

2-3 mm for the material attached for 2,3 and 4 wires

-

2-2,7 mm for the material attached for 7 wires


6.2 T5-ECG

in

Sound

Studios

If electronic control gear for T5/

∅ 16 mm-fluorescent lamps are to be used

in areas in which noise and electromagnetic interference (see also

Section

2.7) are important factors there are special requirements that have to be
met when installing the ECG and the luminaires.

6.2.1 Noise and how to

avoid it

Generally speaking, noise is generated in electronic circuits as a „hum“ (at
50 Hz or 100 Hz) or as higher frequency interference in inductances
(chokes, transformers) and capacitors.

Compared with conventional control gear (chokes), electronic controlgear
with their high-frequency mode of operation (in which inductance values are
much lower) generate appreciably lower noise levels and are a problem
only in highly sensitive environments such as sound studios for CD quality
recordings. The fully electronic control gear for T5/

∅ 16 mm-fluorescent

lamps offered by OSRAM is much quieter than conventional ballasts.
T5/

16 mm-fluorescent lamps can only be operated by electronic

Advertising