electromagnetic field. Serious problems can occur if, as described in
Section xx, wiring instructions, the lamp cables that have high potential with
respect to earth (hot wires) are not kept as short as possible by connecting
them to the nearest lampholder.

The following diagrams apply to both recessed and surface-mounted
luminaires:






3.2.2.6 Asymmetric

installation of ECG


Cables should be laid close to the body of the luminaire. ECG and reflector
need a low resistance earth. Wiring must comply with the
recommendations in Section xx (Installation instructions for luminaires).
The luminaire design provides effective shielding of the electromagnetic
field.

Alternative asymmetric installation


This option is equally suitable.

Lamp

Hot wires

Hot wires

Hot wires