Step 1

Rack Mount iBypass 40G Switch

Install the iBypass 40G Switch into a standard 19-inch equipment rack. The switch is
designed to occupy one rack unit. Do the following to install the iBypass 40G Switch
into an equipment rack:

1. Remove the Ear Extenders and screws from the shipping bag.
2. Attach the Long Ear Extender to the switch if you are only mounting one switch

or attach the Short Ear Extender between two switches if you are mounting two
switches. See Figure 3.

3. Slide the switches in place in the rack.
4. Fasten the switches in place at the front panel ears using the Phillips screws.
5. Make sure the rack is properly electrically grounded.

Grounding

Ground the chassis to the rack by connecting a 14 AWG minimum ground wire with a
#8 ring lug to the ground connection on the rear of the chassis. Terminate the other
end of the ground wire to the rack ground bus bar.