4 Station Bypass Switch with Heartbeat

Link Fault Detect
You can set the bypass switch to drop the remaining full-duplex link when one

side fails. The Link Fault Detect feature ensures that connected devices are

aware of a failure on both sides of the link.

Bypass Detect
You can set the Monitor Ports to cycle on and off while the bypass switch is

in Bypass Enabled mode. In Bypass Detect mode, the Monitor Ports cycle

through five seconds off followed by fifteen seconds on. The alternating link

status can be used to trigger attached devices to send an alarm to a manage-

ment system every time the bypass switch turns off the Monitor Ports. When

the bypass switch returns to Bypass Disabled mode, the Monitor Ports remain

on and the on/off cycle is discontinued.

Note: ________________________________________________________________

All of the following instructions on pages 7-10 will need to be completed

for each segment of the 4 Station Bypass Switch. Before starting, make sure

power to the bypass switch is disconnected.

______________________________________________________________________

To access a bypass switch segment using CLI:
1. Using the RS232 DB-9 cable provided, connect a PC running terminal

emulation software, such as HyperTerminal to the RS232 port on the rear

panel of the bypass switch.

2. Set the terminal emulation software to the following communication

parameters:

9600 baud

8 data bit

No parity

1 stop bit

No flow control

3. Connect power to the bypass switch. The software compile date and time

is displayed in the terminal emulation software as shown in the example

below.

Advertising