Net Optics 4 Station Bypass Switch w_Heartbeat User Manual

Page 9

Advertising
background image

5

4 Station Bypass Switch with Heartbeat

Heartbeat Bypass per Segment

The 4 Station Bypass Switch with Heartbeat protects against both physical

link failure and application failure on the in-line appliance. The switch checks

the path through the in-line appliance by sending a packet every second from

Monitor Port 1. The bypass switch validates the path when it receives the

packet on the Monitor Port 2. If the bypass switch does not receive the packet

as expected three times in a row, the bypass switch automatically enters By-

pass Enabled (ON) mode.You can change the number of the heartbeat packets

required before the bypass switch enters Bypass Enabled mode from the CLI

(see Configuring the Bypass Switch on page 6).

Below is the default IPX heartbeat packet sent once every second from the

Monitor Port 1. You can change the default timing of the heartbeat packet and

the heartbeat packet from the CLI (see Configuring the Bypass Switch on page

6).
Packet Contents (Hex)

Description

-----------------------------

----------------

00 50 C2 3C 60 00 MAC DA Net Optics

00 50 C2 3C 60 01 MAC SA Net Optics

81 37 Packet Type IPX

FF FF 00 30 00 00 00 00

40 04 EC A2 C6 13 01 02

C6 13 01 01 00 00 00 00

00 00 00 00 00 00 00 00

00 00 00 00 00 00 00 00

00 00 00 00 00 00 00 00

82 A2 BA 71 CRC

The switch continues to send the heartbeat packet and will return to Bypass

Disabled mode when it receives three consecutive packets on Monitor Port D.

Advertising