Asus PIKE 1078 User Manual

Page 32

Advertising
background image

2-18

Chapter 2: RAID configuration

2. Click Accept DG to move the

drives to a proposed disk group

configuration in the Disk Groups

window on the right, as shown in

the right figure.

If you need to undo the changes,

click the Back button.

3. When you have finished selecting

physical disks for disk groups, click

Next. The span definition screen

appears Select one of the available

disk groups, and then click Add to

Span.

4. When finish, click Next. The Virtual

Disk Definition screen appears, as

shown in the following figure. You

use this screen to select the RAID

level, strip size, read policy, and other attributes for the new virtual disks.

5. Change the virtual disk options from the defaults listed on the screen as

needed.

Here are brief explanations of the virtual disk options:
RAID Level: The drop-down menu lists the possible RAID levels for the

virtual disk. Select RAID 6.

Strip Size: The strip size specifies the size of the segment written to

each disk in a RAID configuration. You can set the strip size to 8, 16, 32,

64, 128, 256, 512 or 1024 Kbytes. A larger strip size produces higher

read performance. If your computer regularly performs random read

requests, choose a smaller strip size. The default is 64 Kbytes.

Access Policy: Select the type of data access that is allowed for this

virtual disk:

RW: Allow read/write access. This is the default.

Read Only: Allow read-only access.

Blocked: Do not allow access.

Read Policy: Specify the read policy for this virtual drive:

Normal: This disables the read ahead capability. This is the default.

Advertising