Migrating the raid level of a virtual disk – Asus PIKE 1078 User Manual

Page 54

Advertising
background image

2-40

Chapter 2: RAID configuration

Migrating the RAID Level of a Virtual Disk

As the amount of data and the number of disk drives in your system increase,

you can use RAID-level migration to change a virtual disk from one RAID level to

another. You do not have to power down or reboot the system. When you migrate

a virtual disk, you can keep the same number of drives, or you can add drives. You

can use the WebBIOS CU to migrate the RAID level of an existing virtual disk.

While you can apply RAID-level migration at any time, LSI that recommends you

do so when there are no reboots. Many operating systems issues I/O operations

serially (one at a time) during boot. With a RAID-level migration running, a boot

can often take more than 15 minutes.

Migrations are allowed for the following RAID levels:
• RAID 0 to RAID 1
• RAID 0 to RAID 5
• RAID 1 to RAID 5
• RAID 1 to RAID 6
The following table lists the number of additional disk drives required when you

change the RAID level of a virtual disk.
Additional disk Drives Required for RAID-Level Migration

From RAID Level to RAID

Level

Original Number of Disk

Drives in Array

Additional Disk Drives

Required

RAID 0 to RAID 1

RAID 0: 1 drive

1

RAID 0 to RAID 5

RAID 0: 1 drive

2

RAID 1 to RAID 5

RAID 1: 2 drives

1

RAID 1 to RAID 6

RAID 1: 2 drives

1

Follow these steps to migrate the RAID level:

Back up any data that you want to keep before you change the RAID level of

the virtual disk.

1. On the main WebBIOS CU screen, select a virtual disk.
2. When the Virtual Disk screen appears, select Migration only (and skip to

step 5) or Migration with addition in the right panel.

3. If you selected Migration with addition, select one or more physical disks

from the small window in the lower right of the screen.

4. Select a new RAID level from the drop-down menu on the right. The available

RAID levels are limited, based on the current RAID level of the virtual disk

plus the number of physical disks available.

Advertising