Asus PIKE 1078 User Manual

Page 42

Advertising
background image

2-28

Chapter 2: RAID configuration

5. When you have finished selecting

physical disks for the disk groups,

click Next.

The span definition screen appears.

You should add both disk groups

you’ve created in the previous step

to Span section. Select the disk

group in Array With Free Space

section and then click Add to Span.

6. When finish, click Next. The Virtual

Disk Definition screen appears, as shown in the right figure. You use this

screen to select the RAID level, strip size, read policy, and other attributes for

the new virtual disk(s).

7. Hold <Ctrl> while selecting 2 three-drive disk groups in the Configuration

window on the right.

8. Change the virtual disk options from the defaults listed on the screen as

needed.

Here are brief explanations of the virtual disk options:
RAID Level: The drop-down menu lists the possible RAID levels for the

virtual disk. Select RAID 60.

Strip Size: The strip size specifies the size of the segment written to

each disk in a RAID configuration. You can set the strip size to 8, 16, 32,

64, 128, 256, 512 or 1024 Kbytes. A larger strip size produces higher

read performance. If your computer regularly performs random read

requests, choose a smaller strip size. The default is 64 Kbytes.

Access Policy: Select the type of data access that is allowed for this

virtual disk:

RW: Allow read/write access.

Read Only: Allow read-only access. This is the default.

Blocked: Do not allow access.

Read Policy: Specify the read policy for this virtual drive:

Normal: This disables the read ahead capability. This is the default.

Ahead: This enables read ahead capability, which allows the controller

to read sequentially ahead of requested data and to store the additional

data in cache memory, anticipating that the data will be needed soon.

This speeds up reads for sequential data, but there is little improvement

when accessing random data.

Advertising