Connect the optional low-suction pressure switch, Piping checklist – Xylem AquaBoost CS and VS Pumping Packages User Manual

Page 29

Advertising
background image

3. Precharge the tank according to the tank-specific IOM.

Connect the optional low-suction pressure switch

1. If the unit is a simplex configuration, then install the low-suction pressure switch piped

to the 1/4 in. inlet tap on the check valve as shown:

Constant speed

Variable speed

1

RS000023

1.

1/4 in. inlet tap on check valve

1

RS000025

1.

1/4 in. inlet tap on check valve

2. If the unit is a duplex configuration, then install the low-suction pressure switch piped

to the 1/4 in. tap on the suction manifold as shown:

Constant speed

Variable speed

1

RS000024

1.

1/4 in. inlet tap on check valve

1

RS000026

1.

1/4 in. inlet tap on check valve

Piping checklist

WARNING:
• The heating of water and other fluids causes volumetric expansion. The associated forces

can cause the failure of system components and the release of high-temperature fluids.
In order to prevent this, install properly sized and located compression tanks and
pressure-relief valves. Failure to follow these instructions can result in serious personal
injury or death, or property damage.

• Avoid serious personal injury and property damage. Make sure that the flange bolts are

adequately torqued.

• Never force piping to make a connection with a pump.

Check

Explanation/comment

Checked

Check that the suction and discharge pipes are

supported independently by use of pipe hangers near

the pump station.

This eliminates pipe strain on the pump

station.

Installation

AquaBoost CS and VS Pumping Packages Installation, Operation, and Maintenance Manual

27