NOTE: INSURE U-CUP SEAL REMAINS IN ITS

PROPER POSITION DURING COUPLING IN-

STALLATION.

7. Place 2 or 3 drops of LOCTITE

®

#271 on shaft

extension threads. Screw shaft extension into cou-

pling and tighten securely with open end wrenches.

8. Place tube support over motor mounting plate, insert

3 bolts and tighten to 17 ft. lbs. Apply 1 drop of

LOCTITE

®

#243 to each bolt prior to tightening.

9. Press bearing into pump mounting plate.
10. Install restricting bushing with snap ring to pump

mounting plate.

11. Carefully position pump mounting plate assembly

and slide into open end of pump support.

12. Insert 3 bolts and tighten to 17 ft. lbs. Apply 1 drop

of LOCTITE

®

#243 to each bolt prior to tightening.

13. Apply 1 drop of LOCTITE

®

#271 to inside of shaft

sleeve and then slide sleeve over shaft extension.

14. Place key in shaft extension keyseat and slide

impeller over shaft extension. Install impeller bolt

with washer and torque to 17 ft. lbs.

15. Install new O-ring and casing on the pump mounting

plate. Install casing bolts using alternating meth-

od and torque to 17 ft. lbs. Insure casing plug is

installed.

16. Check unit for free turning of impeller prior to pump

startup.

17. Assembly is complete.