Technical data, Voltage change procedure and terminal board design – Xylem IM102 R05 Jet Pumps User Manual

Page 10

Advertising
background image

10

A.O. SMITH / CENTURY MOTOR TERMINAL BOARD AND VOLTAGE CHANGE PLUG

Pumps are Pre-Wired by HP:

• ½ hp wired for 115 volts
• ¾ hp - 1½ hp and larger wired for 230 volts
• 2 hp is 230 volt only

WARNING: DISCONNECT POWER SOURCE BEFORE CHECKING. DO NOT MAKE ANY CHANGES WITH

POWER ON.

TECHNICAL DATA

TECHNICAL DATA

VOLTAGE CHANGES ARE MADE INSIDE THE MOTOR COVER,

NOT IN THE PRESSURE SWITCH.

Fig. 7

DANGER

Hazardous voltage

can shock, burn or

cause death.

DANGER

Hazardous voltage

can shock, burn or

cause death.

A.O. SMITH / CENTURY MOTOR DATA

GWT Number

Where Used

A.O. Smith Number

HP

Volts

Phase

Service Factor

Max. Load Amps

Watts Circuit Breaker

J04853L

J5(S), GB

C48A93A06

½

115/230

1

1.6

10.8/5.4

968

25/15

J05853L

J7(S), GB, GT07, (H)SJ07, HSC07

C48A94A06

¾

115/230

1

1.5

14.8/7.4

1336

30/15

J06853L

J10(S), GB, GT10, (H)SJ10, HSC10

C48A95A06

1

115/230

1

1.4

16.2/8.1

1592

30/20

J07858L

J15(S), GB, GT15, HSJ15, HSC15

C48C53A06

115/230

1

1.3

22.0/11.0

1950

40/20

➀ J08854L

HSJ20, GB, GT20, HSC20

K48A34A06

2

230

1

1.4

12.9

2100

25

J09853

XSH30, GT30

7-196427-20

3

230

1

1.15

13.3

3280

30

SFJ04860

JRS5, JRD5, JB05

C48C04A06

½

115/230

1

1.6

12.6/6.3

990

25/15

SFJ05860

JRS7, JRD7, JB07

C48C05A06

¾

115/230

1

1.5

14.8/7.4

1200

30/15

SFJ06860

JRS10, JRD10, JB10

C48C06A06

1

115/230

1

1.4

16.2/8.1

1400

30/20

Effective July, 1998, 230 V only.

VOLTAGE CHANGE PROCEDURE AND TERMINAL BOARD DESIGN

A.O. Smith jet pump motors have a voltage plug to facilitate simple voltage changes from 115V to 230V. All ½ HP

motors are factory wired for 115V operation. If wired for 115V, operation at 230V will destroy the windings in a

matter of seconds and will not be covered by warranty. Larger HP motors are factory wired at 230V.
Terminal Board Design:

• L1 has two (2) male terminals, one switch wire is attached to one terminal.

• L2 has two (2) male terminals, one switch wire is attached to one terminal and when set up for 115V operation the

voltage plug is connected to the other.

• “A” has 1 male terminal, the voltage plug is always connected to “A”.
Voltage Change: failure to follow these instructions may damage the windings

• 115V - Place the Black voltage plug on the open L2 male terminal and the “A” terminal.

• 230V - Place the Black voltage plug only on the “A” male terminal. The 2nd L2 male terminal will be open.

L1

L2

A

115V

230V

L1

L2

A

115V

230V

Advertising