FLOW DIRECTION AND MOTOR ROTATION
Refer to the above diagram for proper pump installa-
tion detailing fl ow direction and motor rotation. All
SSV units will be properly tagged with fl ow direc-
tion and motor rotation labels. Please ignore all cast
direction arrows. Note that the DPS pump is the
second unit after the lead SSV unit.
CLOCKWISE
ROTATION
DIRECTION
COUNTER-
CLOCKWISE
ROTATION
DIRECTION
CLOCKWISE
ROTATION
DIRECTION
CLOCKWISE
ROTATION
DIRECTION
Series 1SV, 2SV,
3SV and 4SV
Series 5SV and 6SV
(Obsolete)
Size Stage
Operation
Motor
Flange
Flow
Rotation
Orientation
2-16
ALL
CW
A,B,C,D Normal
1SV 18-22 50 Hz, 1750 RPM
CW
A,B,C,D
Normal
18-22 3500
RPM
ONLY CCW
A,B,C,D Reverse
2-15
ALL
CW
A,B,C,D Normal
2SV 16-22 50 Hz, 1750 RPM
CW
A,B,C,D
Normal
16-22 3500
RPM
ONLY CCW
A,B,C,D Reverse
2-13
ALL
CW
A,B,C,D Normal
3SV 14-16 50 HZ, 1750 RPM
CW
A,B,C,D
Normal
14-16 3500
RPM
ONLY CCW
B,C,D Reverse
2-10
ALL
CW
B,C,D Normal
4SV
12
50 Hz, 1750 RPM
CW
B,C,D
Normal
12 3500
RPM
ONLY CCW
B,C,D Reverse