Xylem IM018 R07 G&L SERIES MODEL SSV User Manual

Page 6

Advertising
background image

6

2. MAXIMUM INLET PRESSURE

The following table shows the maximum permissible
inlet pressure. However, the actual inlet pressure +
pressure against a closed valve must always be lower
than the maximum permissible operating pressure.

Pump

Number

Maximum

of Stages

Inlet Pressure

1SV

2-16 Stages

250 psi (17 bar)

17-22 Stages

250 psi (17 bar)

2SV

2-15 Stages

250 psi (17 bar)

16-22 Stages

250 psi (17 bar)

3SV

2-13 Stages

250 psi (17 bar)

14-16 Stages

250 psi (17 bar)

4SV

2-10 Stages

250 psi (17 bar)

11-12 Stages

250 psi (17 bar)

33SV

1-10

Stages

46SV

1-10

Stages

250 psi (17 bar)

66SV

1-6

Stages

92SV

1-6

Stages

3. MAXIMUM OPERATING PRESSURE

(staging at 3500 RPM)

Series

At 250º F

PSI / Bar

1SV

2-16 Stages

325 / 25

17-22 Stages

580 / 40

2SV

2-15 Stages

325 / 25

16-22 Stages

580 / 40

3SV

2-13 Stages

325 / 25

14-16 Stages

580 / 40

4SV

2-10 Stages

325 / 25

11-12 Stages

580 / 40

33SV

1-6 Stages

362 / 25

7-10 Stages

580 / 40

46SV

1-5 Stages

362 / 25

6-10 Stages

580 / 40

66SV

1-5 Stages

362 / 25

6 Stages

580 / 40

92SV 1-5

Stages 362

/

25

NOTE: Oval fl ange (1-3SV) maximum working
pressure is 232 psi (16 bar).

4. TEMPERATURE CAPABILITY

The SSV pump is capable of pumping liquids within
the below temperature range:

1-4SV

-22º F to 250º F (-30º C to 120º C)

33SV-92SV

-22º F to 250º F (-30º C to 120º C)

NOTE: In order to provide adequate cooling for the

electric motor, the ambient temperature must
be 32º F to 104º F and the relative humidity at
104º F must not exceed 50%.

For temperatures above 104º F and for installations
sites located at elevation in excess at 3000 feet above
sea level it may be necessary to derate the motor
performance. Please contact your distributor/dealer for
assistance.

WARNING

5. MINIMUM NOMINAL FLOW RATE

To prevent overheating of the internal pump com-
ponents, make sure that a minimum water fl ow is
always guaranteed when the pump is running.

For continuous operation the minimum fl ow rate
recommended is specifi ed below.

Pump

Size

1SV 2SV 3SV 4SV

Min. Flow 3500

RPM 3 6 12 17

(gpm) 2900

RPM 3 6 10 14

Pump Size

33SV 46SV 66SV 92SV

Min. Flow 3500

RPM

35 40 70 100

(gpm) 2900

RPM 8 10 14 20

NOTE: If this cannot be archived, then a bypass/
recirculate line is recommended.

Do not run the pump against a closed
discharge for longer than a few seconds.

6. NUMBER OF STARTS PER HOUR

For electric pumps coupled to motors supplied by
Goulds Pumps, the maximum number of work cycles
(starts and stops) in one hour are as follows:

HP

3

/

4

-3 5-10 15-20

25-75

# of Starts 5 5 5 5

For more details, refer to technical manual.

If you use a different motor from
the standard one supplied by Goulds

Pumps, please consult with the motor manufacturer
to fi nd out the maximum number of work cycles
allowed.

7. POWER SUPPLY REQUIREMENTS

Make sure that the supply voltages
and frequencies are suited to the

characteristics of the electric motor. Check the
motor rating plate.

In general, the supply voltage tolerances for motor
operation are as follows:

U

N

Hz Phase

V

±%

60

1

230

10

60

3

230 / 460

10

60

3

460

10

1. TRANSPORTATION AND HANDLING OF
PACKED PRODUCT

The SSV pump is packed in cartons or wooden
crates having different dimensions and shapes.

Some cartons (the supporting base
is made of wood) are designed to be

transported and handled in the vertical position.
Other cartons, as well as the wooden crates, are
designed to be transported and handled in the hori-
zontal position. Protect the product against humid-
ity, heat sources and mechanical damage (collisions,
falls, ...). Do not place heavy weights on the cartons.

WARNING

WARNING

WARNING

Advertising