7.7 The electric pump starts, but the system's
residual current device (RCD) is activated

Cause

Remedy

There is an ground

(earth) leakage.

Check the insulation of the electrical system

components.

7.8 The pump runs but delivers too little or no
liquid

Cause

Remedy

There is air inside the

pump or the piping.

• Bleed the air

The pump is not correctly

primed.

Stop the pump and repeat the prime pro-

cedure.
If the problem continues:

• Check that the mechanical seal is

not leaking.

• Check the suction pipe for perfect

tightness.

• Replace any valves that are leaking.

The throttling on the deliv-

ery side is too extensive.

Open the valve.

Valves are locked in closed

or partially closed position.

Disassemble and clean the valves.

The pump is clogged.

Contact the local sales and service repre-

sentative.

The piping is clogged.

Check and clean the pipes.

The rotation direction of

the impeller is wrong
(three-phase version)
.

Change the position of two of the phases

on the terminal board of the motor or in

the electric control panel.

The suction lift is too high

or the flow resistance in

the suction pipes is too

great.

Check the operating conditions of the

pump. If necessary, do the following:

• Decrease the suction lift

• Increase the diameter of the suction

pipe

7.9 The electric pump stops, and then rotates
in the wrong direction

Cause

Remedy

There is a leakage in one or both of the follow-

ing components:

• The suction pipe

• The foot valve or the check valve

Repair or replace the

faulty component.

There is air in the suction pipe.

Bleed the air.

7.10 The pump starts up too frequently

Cause

Remedy

There is a leakage in one or both of the fol-

lowing components:

• The suction pipe

• The foot valve or the check valve

Repair or replace the

faulty component.

There is a ruptured membrane or no air

pre-charge in the pressure tank.

See the relevant instruc-

tions in the pressure

tank manual.

7.11 The pump vibrates and generates too
much noise

Cause

Remedy

Pump cavitation

Reduce the required flow rate by partially closing

the on-off valve downstream from the pump. If the

problem persists check the operating conditions of

the pump (for example height difference, flow re-

sistance, liquid temperature).

Cause

Remedy

The motor bear-

ings are worn.

Contact the local sales and service representa-

tive.

There are foreign

objects inside the

pump.

Contact the local sales and service representa-

tive.

For any other situation, refer to the local sales and service representa-

tive.