3.1.2 Mechanical mounting
Variant for HVS 1.1
1. Remove the motor fan cover from
your 3-phase motor by removing the
mounting screws.
2. Put the mounting and distance ring
(1) between the fan cover and the
Hydrovar sensorless and fix them
together with the screw (3) by using
the included washer (2).
3. Use the fan cover screws to mount
the fan cover/Hydrovar sensorless
combination to the motor
CAUTION!:
Don’t forget the washer between the screw and the motor fan cover!
Hydrovar
sensorless
(1) mounting
and distance
ring
motor fan
cover
(2) washer
(3) screw