Dissolved oxygen transmitter – Xylem Oxix Dissolved Oxygen Transmitter User Manual

Page 65

Advertising
background image

65

Dissolved Oxygen Transmitter

GB Oxix Manual 080915

FW: 841013-009, 846001-002, 841513-009

Product Data
Key product data like ID, hardware type no., track no. and HW type no.

are displayed.

Sensor Data

Sensor Calibration

Converter SW. Version.

Product data

Reset Counter Time

Internal meas. & cal.

Calibrate mA

Test Primary value

Read eventlog

Comunication log

Back On Stock

Autodetect sensor type

Main supply frequency

Back Select OK

Sensor data

Sensor serial number

30487

Sensor software version

2

Back OK

Converter SW version

Converter 846001-002

195

Bootload 840020-002

684

Back

Product data

Product ID

000000000000

Back Select >

HW type no

0510305004

Back Select >

Track no

00000

Back Select >

Product type no

00000206305

Back Select >

Set actual measurement

10,20 mg/l

Back Select

OK

Sensor calibration

Sensor calibration

1 point calibration

2 point calibration

Cancel

Back Select

OK

OK

Clear calibration

No

Yes

Back Select

OK

Confirm zero oxygen

No

Yes

Back Select

OK

1 point

2 point

Calibrate Vcc

Calibrate V_ref

Back Select OK

Internal meas. & cal.

View Vcc

- - - -

Back Select OK

Calibrate Vcc

- - - -

Back Select >

View V_ref

- - - -

Back Select OK

Calibrate Vref

- - - -

Back Select >

Reset counter time

Reset Counter 1

System Runtime 2304

Since Reset 2304

Runtime (days)

0

Back Select OK

Set actual measurement

10,20 mg/l

Back Select

OK

Type password

00000

Back Select >

Service menu

GB Oxix menuer #1 Service menu 1

FW: 841013-009, 846001-002, 841513-009

Page 5 of 7 15. september 2008

Reset Counter Time
The counter can be reset for fault finding, error correction and similar

service procedures, and the actual runtime is displayed.

Sensor Data

Sensor Calibration

Converter SW. Version.

Product data

Reset Counter Time

Internal meas. & cal.

Calibrate mA

Test Primary value

Read eventlog

Comunication log

Back On Stock

Autodetect sensor type

Main supply frequency

Back Select OK

Sensor data

Sensor serial number

30487

Sensor software version

2

Back OK

Converter SW version

Converter 846001-002

195

Bootload 840020-002

684

Back

Product data

Product ID

000000000000

Back Select >

HW type no

0510305004

Back Select >

Track no

00000

Back Select >

Product type no

00000206305

Back Select >

Set actual measurement

10,20 mg/l

Back Select

OK

Sensor calibration

Sensor calibration

1 point calibration

2 point calibration

Cancel

Back Select

OK

OK

Clear calibration

No

Yes

Back Select

OK

Confirm zero oxygen

No

Yes

Back Select

OK

1 point

2 point

Calibrate Vcc

Calibrate V_ref

Back Select OK

Internal meas. & cal.

View Vcc

- - - -

Back Select OK

Calibrate Vcc

- - - -

Back Select >

View V_ref

- - - -

Back Select OK

Calibrate Vref

- - - -

Back Select >

Reset counter time

Reset Counter 1

System Runtime 2304

Since Reset 2304

Runtime (days)

0

Back Select OK

Set actual measurement

10,20 mg/l

Back Select

OK

Type password

00000

Back Select >

Service menu

GB Oxix menuer #1 Service menu 1

FW: 841013-009, 846001-002, 841513-009

Page 5 of 7 15. september 2008

Advertising