Model l, ln, Page 57 – Xylem LN User Manual

Page 61

Advertising
background image

Installation, Operating and Maintenance Instruction

Model L, LN


Page 57

D

ischarge too l

o

w

D

ischarge stops after a ti

me

H

ead too l

o

w

H

ead too hi

gh

D

ri

v

e mechani

sm overl

oaded

P

u

mp not runni

ng qui

etl

y

Temperature i

n

pump too hi

gh

Temperature i

n

shaft seal

ing too hi

gh

Temperature at the beari

ng too hi

gh

P

u

mp l

eaki

ng

Leakage rate at shaft seal

ing too hi

gh

Cause

Solution

■

Back-pressure

too

high

check facility for pollution, open discharge valve
reduce resistance in discharge pipe (e.g. clean filter if
necessary)
use larger impeller (note available motor power)

■

■

■

Back-pressure too low, discharge too low

throttle discharge valve

■ ■

Speed

too

high

reduce

speed

compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check refer-
ence value setting

■

■

Speed

too

low

increase speed (check available motor power)
compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value settings

■ ■

■ ■

Flow too little

increase min. flow (open discharge valve, bypass)

■

Flow too big

reduce flow (throttle discharge valve)

■ ■

Impeller diameter too big

use smaller impeller

■

■

Impeller diameter too small

use larger impeller (check available motor power)

■

■

■ ■

Pump and/or pipes not completely filled with liquid

fill
vent

■ ■ ■

Pump

or

suction/intake

pipe

blocked

clean

■

■

Air

pocket

in

pipeline

vent
improve course of pipe

■ ■ ■

■ ■

Suction height too big / NPSH of system too small

increase liquid level and admission pressure
reduce resistance in the intake/suction pipe (change course
and rated width, open shut-off valves, clean filters)

■ ■ ■

Air being sucked in

increase liquid level
check if suction pipe is vacuum-tight

■ ■ ■

Air being sucked in through shaft sealing

clean sealing pipe
increase sealing pressure
replace shaft sealing

■

■

Direction

of

rotation

is

wrong

swap

over two phases of power supply (to be done by an

electrician)

■

■

■

■

Inner components suffering from wear

replace worn parts

■

■

■

Density and/or viscosity of liquid handled is too high

seek assistance

■

■

Lines and roughness on shaft or shaft sleeve

replace parts

■

■

Deposits on mechanical seal

clean
replace mechanical seal if necessary
if necessary provide additional rinsing or quench

■

■

Impeller out of balance

remove blocks/deposits
replace impeller if broken or unevenly worn
check shafts to ensure that they are running true

■

■

■

Coupling not aligned

align pump unit better

■

■

Coupling distance too small

change

■ ■

■ ■ ■

Forces in pipeline too high (pump unit under strain)

change (support pipes, use compensators, etc.)
is foundation plate/frame properly cast in place?

■

Too much, too little or the wrong type of lubricant

change

■

Electricity supply not right (2-phase running)

check voltage of all phases
check cable connections and fuses

■

Sealing insufficient

tighten screws
replace sealing

■

■ Bearing

damaged

replace
check lubricant and bearing space for pollutants (rinse oil area)

■ Relief

fittings

insufficient

clean relief openings in impeller
replace worn parts (impeller, split rings)
adjust in line with the system pressure/intake pressure given on
ordering

■

System-related vibrations (resonance)

seek assistance









Advertising