Problem
Possible cause
Solution
The entire
image is too
soft.
Sharpness setting is too low.
Select Picture>Sharpness and increase
the sharpness setting.
Active pixels are incorrect.
Select Picture>Advance>Active Pixels
and reduce the setting to match the
input signal.
Total pixels setting is
incorrect.
Select Picture>Advanced>Total Pixels
and experiment with settings until the
characters are sharp.
Some
characters are
too soft.
Total pixels setting is
incorrect.
Select Picture>Advanced>Total Pixels
and experiment with settings until the
characters are sharp.
Input phase setting is
incorrect.
Select Picture>Advance>Fine Phase
and experiment with settings until the
characters are sharp.
DVI PC source
does not
output desired
resolution.
EDID incorrectly set.
Set EDID data to match the desired
resolution (see “
”).