Preliminary – Extron Electronics MGP 462xi Series User Manual

Page 73

Advertising
background image

4-21

MGP Series • Softwar

e Configuration and Contr

ol

PRELIMINARY

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

(host to processor)

Response

(processor to host)

Additional description

Information requests

General information

X50@

* I

Chn

X50)

• Typ

X50#

• Std

X50(

• Blk

X%

]

View input number, video signal type, input signal
standard, and blanking (muting) status in window

X50@

.

X50)

= 1 through 19.

X50#

= signal type. For

X50#

:

1 = RGB 5 = S-video
2 = YUV-HD 6 = Composite video
3 = RGBcvS 7 = DVI/HD-SDI
4 = YUVi

X50(

= signal standard. For

X50(

:

0 = None 4 = SECAM
1 = NTSC = Not applicable
2 = PAL

X%

= muting status. For

X%

:

1 = muted; 0 = unmuted

Query firmware version

Q

x.xx

]

View firmware version number x.xx.

Query part number

N

60-771-xx or 60-1023-xx

]

View the MGP's part number.
60-771-xx = MGP 464 series
60-1023-xx = MGP 462xi series
For xx:
-01 = standard model
-02 = DI model
-03 = HD-SDI model

View internal temperature

20S

X51(

]

View internal temperature

X51(

in degrees

Fahrenheit.

With tagged response – Verbose modes 2 and 3:
Sts20 *

X51(

]

Advertising
This manual is related to the following products: