Low level configuration – Extron Electronics VN-Matrix 300 User Guide User Manual

Page 24

Advertising
background image

VN-Matrix 300 • Installation and Basic Setup Procedures

18

z

On the PC run a terminal emulation program such as HyperTerminal, with the following
comms settings:

Baud rate:

115200

Data bits:

8

Parity:

None

Stop bits:

1

Flow control:

None

Low level configuration

z

Connect the power to the VN-Matrix 300 (or, if already connected, cycle the power off
then on).

z

The VN-Matrix 300 will commence sending setup/diagnostic data which should appear
in the HyperTerminal window. After a few seconds the diagnostic data will stop and you
will see a flashing cursor in the Hyperterminal window.

z

Press the <Enter> key — the VN-Matrix 300 should respond with the following login
prompt:

VN Matrix(R) Maintenance Console: ver n.n
192.168.0.1 login:

NOTE: The login prompt will be preceded by the current IP Address of the unit.

z

Type

config

and press the <Enter> key.

z

When prompted for a password type

config

and press the <Enter> key.

z

The following menu will then appear.

NOTE: The IP addresses here are for illustration and may not match those on your

unit.

Network Port 1 Network Port 2

============== ==============

0. Speed/Duplex: auto_10_100_1000 10. Speed/Duplex: fibre_fixed_1000F

1. Boot method: static [dhcp] 11. Boot method: static [dhcp]

2. address: 192.168.0.104 12. address: 192.168.1.2

3. netmask: 255.255.255.0 13. netmask: 255.255.255.0

4. gateway: 14. gateway:

5. broadcast: 15. broadcast: 192.168.1.255

6. mtu: 1500 16. mtu: 1500

7. controller ip: 192.168.0.101 17. ip forwarding: 0

8. controller port: 80 18. webserver port: 80

9. Exit

Please select an option:

RJ-45 Network Port

Optical Network Port

Advertising