VN-Matrix 300 • Installation and Basic Setup Procedures
18
z
On the PC run a terminal emulation program such as HyperTerminal, with the following
comms settings:
Baud rate:
115200
Data bits:
8
Parity:
None
Stop bits:
1
Flow control:
None
Low level configuration
z
Connect the power to the VN-Matrix 300 (or, if already connected, cycle the power off
then on).
z
The VN-Matrix 300 will commence sending setup/diagnostic data which should appear
in the HyperTerminal window. After a few seconds the diagnostic data will stop and you
will see a flashing cursor in the Hyperterminal window.
z
Press the <Enter> key — the VN-Matrix 300 should respond with the following login
prompt:
VN Matrix(R) Maintenance Console: ver n.n
192.168.0.1 login:
NOTE: The login prompt will be preceded by the current IP Address of the unit.
z
Type
config
and press the <Enter> key.
z
When prompted for a password type
config
and press the <Enter> key.
z
The following menu will then appear.
NOTE: The IP addresses here are for illustration and may not match those on your
unit.
Network Port 1 Network Port 2
============== ==============
0. Speed/Duplex: auto_10_100_1000 10. Speed/Duplex: fibre_fixed_1000F
1. Boot method: static [dhcp] 11. Boot method: static [dhcp]
2. address: 192.168.0.104 12. address: 192.168.1.2
3. netmask: 255.255.255.0 13. netmask: 255.255.255.0
4. gateway: 14. gateway:
5. broadcast: 15. broadcast: 192.168.1.255
6. mtu: 1500 16. mtu: 1500
7. controller ip: 192.168.0.101 17. ip forwarding: 0
8. controller port: 80 18. webserver port: 80
9. Exit
Please select an option:
RJ-45 Network Port
Optical Network Port