Serial port control, Pass-through control mode, Serial port control pass-through control mode – Extron Electronics VN-Matrix 300 User Guide User Manual

Page 55: Device page — peripherals

Advertising
background image

VN-Matrix 300 • System Configuration

49

Bit rate and network statistics for the current stream are reported in a tabular form.

z

The total column contains counts for the history of the stream.

z

The window1 and window2 columns contain counts over user programmable
intervals.

z

Megabits/sec

—

The bit rate received from the current data source.

NOTE: The reported bit rate is for the video stream only. Statistics are available

for

Audio and FEC

on page 45.

z

Packets/sec

—

The number of data packets per second received from the source.

z

Dropped packets

—

The number of data packets dropped during the associated

interval time. This will always be 0 for TCP streams.
Dropped packets will be counted when using RTP streams on busy networks.

z

Interval time

—

The time over which the previous counts are averaged.

The total column assumes an interval time of infinity. The remaining two times are user
programmable in seconds.

Device Page — Peripherals

Serial Port Control

Bi-directional serial communications (RS-232) can be achieved between any VN-Matrix 300
units on a network.
Serial data is sent independently of the other streams on the network and it is not necessary
to have a direct encoder to decoder relationship.

Pass-through Control Mode

In this mode, serial data is passed from one VN-Matrix 300 device to another. Data flow
is fully bi-directional and is independent of whether the VN-Matrix 300 is an encoder or
decoder. Thus control of external equipment is supported.

Figure 36.

Pass-through Control

A single VN-Matrix 300 device is designated the server. One or more VN-Matrix 300 devices
are then configured as clients.

Advertising