Routed network configuration example – Extron Electronics VN-Matrix 300 User Guide User Manual

Page 30

Advertising
background image

VN-Matrix 300 • Installation and Basic Setup Procedures

24

Routed Network Configuration Example

NOTES: This is an example of a routed network configuration.

•

Unit 1 is configured as the controller, on IP address 192.168.0.1.

The two VN-Matrix 300 units are connected across a WAN via an external
router.

•

A gateway IP address is now set on NIC port 2 (option 14).

•

Only 1 gateway may be assigned.

Image data is transported over NIC 2 (the SFP connector).

•

The port used for image data transfer is set in the WEB interface, described

later.

Browser control is available on either NIC

•

Enter the IP address of the appropriate NIC in the browser address bar.

A network management system connected via NIC 1 (RJ45).

•

This provides isolation between image and SNMP traffic.

NIC2:192.168.0.1

NIC1:172.28.0.1

NIC2:192.168.1.1

NIC1:172.29.1.1

Local NMS server

172.28.0.3

Browser address

192.168.0.1

Unit 1

Unit 2

Controller

Switch

Switch

Switch

Switch

Browser (NIC1)

172.28.0.4

192.168.0.250

192.168.1.250

Browser (NIC1)

172.29.1.4

Local NMS server

172.29.1.3

Local SNMP

Browser (NIC2)

192.168.0.3

Browser address

172.28.0.1

Unit 1

Network Port 1 (RJ45)

Network Port 2 (SFP)

1

Boot method: static [dhcp]

11

Boot method: static [dhcp]

2

Address: 172.28.0.1

12

Address: 192.168.1.1

3

Netmask: 255.255.0.0

13

Netmask: 255.255.255.0

14

Gateway: 192.168.0.250

5

Broadcast:

15

Broadcast:

6

Mtu: 1500

16

Mtu: 1500

17

Controller ip: 192.168.0.1

8

Controller port: 5432

18

Webserver port: 80

9

Exit