Alarm type description — decoder, Alarm type description — controller, Controller – Extron Electronics VN-Matrix 300 User Guide User Manual
Page 70: Overview — snmp

VN-Matrix 300 • Alarms and SNMP
64
Alarm Type Description — Decoder
Alarm Type
Description
Action
Default Settings
Decoder Alarm
No decoder video data
Indicates that there is a valid
connection, no video data present.
Usually accompanied by no source
data stream message in the WEB
interface.
Warning, reporting
No decoder mode
No matching decoder mode for the
incoming stream.
Warning, reporting
No source report
Unable to detect the format of the
received data stream.
Warning, reporting
Recovered audio
Not applicable to VN-Matrix 300
N/A
No decoder audio data
Not applicable to VN-Matrix 300
N/A
Bad audio at decoder
Not applicable to VN-Matrix 300
N/A
Bad audio PLL
Not applicable to VN-Matrix 300
N/A
Video network packets
dropped
Excessive network packet loss has
occurred.
Warning, reporting
Decoder buffer overflow The incoming data rate is high;
reduce the pipeline delay.
Warning, reporting
Decoder buffer
underflow
The incoming data rate is too low;
increase the pipeline delay
Warning, reporting
Bad video PLL
The decoder cannot synchronize to
the video data.
Warning, reporting
No decoder ANC data
The decoder is not receiving any
embedded audio (ancillary) data.
Warning, reporting
Missing ANC at decoder The Decoder is receiving poor
quality ANC data
Warning, reporting
Recovered ANC
Error correction has recovered
corrupted / missing ANC.
Warning, reporting
Alarm Type Description
—
Controller
Alarm Type Description
Action
Default Settings
Contr
oller
Alarm
Bad device
The Controller is unable
to contact the specified
device. The device is not
available or has failed.
Check the device in question
z
Is power applied?
z
Is the network cable / connection
present?
z
Has the unit been removed?
Critical, reporting