External supply protection – Extron Electronics VN-QUANTUM User Guide User Manual
Page 22

Section 1: Installation & Setup
VN-QUANTUM User Guide
Page 22
I455GB issue 8
External Supply Protection
The mains power cord must be protected from overload by an external fuse or
circuit breaker.
Fused Plugs (UK-style)
If the power cord is fitted with a UK-style BS1363 3-pin plug (i.e. with provision for an internal fuse),
then it must be fitted with a BS1362 ASTA approved 1 inch cartridge fuse rated at 10A/250V.
Unfused Plugs or Hard-wired Installation
If the power cord is fitted with an unfused plug, or is hard-wired into a power strip (mains distribution
batten), then the power cord must be protected by an external fuse or circuit breaker of a rating
shown in the table below:
Supply Voltage
110V nominal
230V nominal
Fuse Rating
13A
10A
WARNING: Never attempt to fit a fuse or circuit breaker of a higher rating.