Connecting the Control PC
VN-QUANTUM has a dedicated CONTROL port for the connection of a PC or laptop, running VN-
COMMANDER application software.
Connection between the CONTROL port and the PC or laptop must be made using a CAT5 crossover
patch cable (a 5m/16ft cable is supplied).
Control Port Settings
The VN-QUANTUM is shipped with the CONTROL port set to the following:
IP Address
172.28.232.11
Subnet Mask
255.255.000.000
Default Gateway
0.0.0.0
DNS Server
0.0.0.0
WINS Server
0.0.0.0
Name
VNQuantum
NOTE: The CONTROL port does not support DHCP operation.
To enable communications between the computer and VN-QUANTUM you must ensure that the IP
Address and Subnet Mask settings are compatible on both devices:
The Subnet Mask for both devices must be the same.
The IP Address must be different, but in the same class/subnet.
To change the settings the VN-QUANTUM CONTROL port, follow the procedure on page 36.