Connecting the control pc, Control port settings – Extron Electronics VN-QUANTUM User Guide User Manual

Page 37

Advertising
background image

VN-QUANTUM User Guide

Section 1: Installation & Setup

I455GB issue 8

Page 37

Connecting the Control PC


VN-QUANTUM has a dedicated CONTROL port for the connection of a PC or laptop, running VN-
COMMANDER application software.

Connection between the CONTROL port and the PC or laptop must be made using a CAT5 crossover
patch cable (a 5m/16ft cable is supplied).

Control Port Settings


The VN-QUANTUM is shipped with the CONTROL port set to the following:

IP Address

172.28.232.11

Subnet Mask

255.255.000.000

Default Gateway

0.0.0.0

DNS Server

0.0.0.0

WINS Server

0.0.0.0

Name

VNQuantum


NOTE: The CONTROL port does not support DHCP operation.

To enable communications between the computer and VN-QUANTUM you must ensure that the IP
Address and Subnet Mask settings are compatible on both devices:

The Subnet Mask for both devices must be the same.

The IP Address must be different, but in the same class/subnet.


To change the settings the VN-QUANTUM CONTROL port, follow the procedure on page 36.

For further help on IP Addressing, see Appendix A.

Advertising