Product level measurement – values – Franklin Fueling Systems Tank Sentinel (TS-1001, 2001, 504, 508 & 750) Installation User Manual
Page 25

3
Page
3 - 2
TANK SENTINEL
®
INSTALLATION GUIDE
Figure 3-2.
Typical Tank – Fill & Probe on the Same Side of the Tank Center
Product Level Measurement – values
You must measure the product level at two points in the tank to determine the
degree to which it is tilted. A level measurement is made at the fill pipe (drop tube)
and at the location where the level probe will be installed. Record these level
measurements for each tank in the spaces provided below.
The tank must have liquid in it before these measurements are taken. If a tank is
empty, collect all of the other data until the tank has been at least partially filled,
and then take these level measurements.
Level at:
FILL (LF)
PROBE (LP)
FILL (LF)
PROBE (LP)
TANK 1
TANK 2
TANK 3
TANK 4
TANK 5
TANK 6
TANK 7
TANK 8
The blank fields for tanks 5 though 8 are for Tank Sentinel
®
consoles, Model
numbers: TS-2001 and TS-508 only (this is true throughout this manual).
NOTE
WATER
LENGTH OF TANK
Fill
" XP "
" XF "
AIR
FUEL
FUEL
PRODUCT
LEVEL
Tank
shown
tilted
Fill & Probe on
the same side of
the tank
Product / Water
Offset =
CENTER OF TANK
level
Probe
" LP "
Level
at Probe
L
C
TANK
DIAMETER
" LF "
Level
at Fill
(LF - LP) * XP
XP - XF
DROP TUBE
TOP OF TANK