4. Operation

4-9

031-093-C0-001 © 3/99

8.

Dual Fuel Load Block conversion from Natural Gas to Liquid Propane Gas.

Procedure:

1.

Remove the blanking plug from the lower outlet port on the load

block.

2.

Loosen the hose clamp on the fuel supply hose at the load block.

3.

Loosen the brass fitting and remove from the upper outlet port (NG

port) and install in the lower outlet port (LP port).

4.

Retighten the hose clamp.

5.

Install the blanking plug into the upper outlet port.

NOTE :

Apply a high-quality gas pipe thread sealant to the

blanking plug and brass fitting threads.

4.4

Converting APU From Natural Gas To Propane Gas, cont.

1

2,4

3

5

Figure 4.14,Dual fuel load block