Alpha Technologies CE-G Series User Manual

Page 35

Advertising
background image

4. Operation

4-10

031-093-C0-001 © 3/99

9.

Reconnect the APU exhaust and Fuel Hose

Procedure:

1.

Install new gasket at the exhaust Flex pipe flange.

2.

Apply anti–seize compound to the flange bolts and install into flange

3.

Torque the exhaust pipe flange bolts, bolt to bolt, to 7-ft/pounds.

4. Reconnect the fuel hose with cable ties to the proper anchor points (see

below). Verify the chafe guard is properly seated in the cut out before the

APU drawer is closed.

5. Once the fuel hose is securely fastened, slide the APU drawer back in the

enclosure and re-fasten the retaining bolts.

4.4

Converting APU From Natural Gas To Propane Gas, cont.

Figure 4.16, Fuel hose placement, APU

Figure 4.15, Exhaust pipe flange gasket

NOTE:

Verify fuel hose

is completely

wrapped in

chafe guard

material and

fully seated in

cutout.

Advertising