Atec Rohde-Schwarz-ZVA Series User Manual

Page 18

Advertising
background image

Version 10.00, May 2012

18

Rohde & Schwarz

R&S

®

ZVA Vector Network Analyzer

Accuracy of reflection measurements
R&S

®

ZVA8

300 kHz to 1 MHz

for +10 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

1 MHz to 8 GHz

for +10 dB to +3 dB

< 0.6 dB or < 4°

for +3 dB to –15 dB

< 0.4 dB or < 3°

for –15 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

R&S

®

ZVA24

10 MHz to 50 MHz

for +3 dB to –15 dB

< 1 dB or < 6°

for –15 dB to –25 dB

< 3 dB or < 20°

50 MHz to 24 GHz

for +10 dB to +3 dB

< 0.6 dB or < 4°

for +3 dB to –15 dB

< 0.4 dB or < 3°

for –15 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

R&S

®

ZVA40

10 MHz to 50 MHz

for +3 dB to –15 dB

< 1 dB or < 6°

for –15 dB to –25 dB

< 3 dB or < 20°

50 MHz to 40 GHz

for +10 dB to +3 dB

< 0.6 dB or < 4°

for +3 dB to –15 dB

< 0.4 dB or < 3°

for –15 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

R&S

®

ZVA50

10 MHz to 50 MHz

for +3 dB to –15 dB

< 1 dB or < 6°

for –15 dB to –25 dB

< 3 dB or < 20°

50 MHz to 50 GHz

for +10 dB to +3 dB

< 0.6 dB or < 4°

for +3 dB to –15 dB

< 0.4 dB or < 3°

for –15 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

R&S

®

ZVA67

10 MHz to 50 MHz

for +3 dB to –15 dB

< 1 dB or < 6°

for –15 dB to –25 dB

< 3 dB or < 20°

50 MHz to 67 GHz

for +10 dB to +3 dB

< 0.6 dB or < 4°

for +3 dB to –15 dB

< 0.4 dB or < 3°

for –15 dB to –25 dB

< 1 dB or < 6°

for –25 dB to –35 dB

< 3 dB or < 20°

Specifications are based on an isolating DUT, a measurement bandwidth of 10 Hz, and a nominal source power of –10 dBm.

Magnitude

0.00

0.01

0.02

0.03

0.04

0.05

0

0.2

0.4

0.6

0.8

1

Reflection coefficient (linear)

U

n

c

e

rt

a

int

y

(

line

a

r)

Phase

0

2

4

6

8

10

0

0.2

0.4

0.6

0.8

1

Reflection coefficient (linear)

U

n

c

e

rta

in

ty

/

d

e

g

Diagram: Typical accuracy of reflection magnitude and reflection phase measurements

of the R&S

®

ZVA8 in the frequency range 1 MHz to 8 GHz,

of the R&S

®

ZVA24 in the frequency range 50 MHz to 24 GHz,

of the R&S

®

ZVA40 in the frequency range 50 MHz to 40 GHz,

of the R&S

®

ZVA50 in the frequency range 50 MHz to 50 GHz,

and of the R&S

®

ZVA67 in the frequency range 50 MHz to 67 GHz.