ZVA Vector Network Analyzer

Noise level
(without optional step attenuators
and without optional direct
generator/receiver access)

at 10 Hz measurement bandwidth
R&S

®

ZVA8

300 kHz to 100 MHz

< –100 dBm

100 MHz to 8 GHz

< –115 dBm

R&S

®

ZVA24

10 MHz to 100 MHz

typ. < –80 dBm

100 MHz to 700 MHz

< –80 dBm

700 MHz to 2 GHz

< –110 dBm

2 GHz to 13 GHz

< –115 dBm

13 GHz to 24 GHz

< –110 dBm

R&S

®

ZVA40

10 MHz to 100 MHz

typ. < –80 dBm

100 MHz to 500 MHz

< –80 dBm

500 MHz to 2 GHz

< –110 dBm

2 GHz to 20 GHz

< –115 dBm

20 GHz to 24 GHz

< –110 dBm

24 GHz to 32 GHz

< –105 dBm

32 GHz to 40 GHz

< –100 dBm

R&S

®

ZVA50

10 MHz to 100 MHz

typ. < –80 dBm

100 MHz to 500 MHz

< –100 dBm

500 MHz to 24 GHz

< –115 dBm

24 GHz to 40 GHz

< –110 dBm

40 GHz to 50 GHz

< –100 dBm

R&S

®

ZVA67

10 MHz to 100 MHz

typ. < –80 dBm

100 MHz to 500 MHz

< –105 dBm

500 MHz to 2 GHz

< –110 dBm

2 GHz to 24 GHz

< –118 dBm

24 GHz to 40 GHz

< –105 dBm

40 GHz to 50 GHz

< –102 dBm

50 GHz to 67 GHz

< –100 dBm

Noise level at optional measurement input
(direct generator/receiver access option)

at 10 Hz measurement bandwidth
R&S

®

ZVA8

100 MHz to 8 GHz

typ. < –130 dBm

R&S

®

ZVA24

100 MHz to 24 GHz

typ. < –130 dBm

R&S

®

ZVA40

100 MHz to 24 GHz

typ. < –130 dBm

24 GHz to 40 GHz

typ. < –120 dBm

R&S

®

ZVA50

100 MHz to 24 GHz

typ. < –130 dBm

24 GHz to 40 GHz

typ. < –120 dBm

40 GHz to 50 GHz

typ. < –115 dBm

R&S

®

ZVA67

100 MHz to 24 GHz

typ. < –130 dBm

24 GHz to 40 GHz

typ. < –120 dBm

40 GHz to 50 GHz

typ. < –115 dBm

50 GHz to 67 GHz

typ. < –110 dBm

The noise level is defined as the RMS value of the indicated noise floor. For the R&S

®

ZVA67 at single frequencies below 2.5 GHz,

the noise level may be affected by spurious signals.