ZVA Vector Network Analyzer 25
Test port input
Match
without system error correction
R&S
®
ZVA8
300 kHz to 7 GHz
> 16 dB
7 GHz to 8 GHz
> 14 dB
R&S
®
ZVA24
10 MHz to 50 MHz
> 10 dB
50 MHz to 2 GHz
> 12 dB
2 GHz to 24 GHz
> 8 dB
R&S
®
ZVA40
10 MHz to 4 GHz
> 12 dB
4 GHz to 20 GHz
> 8 dB
20 GHz to 40 GHz
> 6 dB
R&S
®
ZVA50
10 MHz to 50 MHz
> 8 dB
50 MHz to 10 GHz
> 10 dB
10 GHz to 20 GHz
> 8 dB
20 GHz to 40 GHz
> 6 dB
40 GHz to 50 GHz
> 5 dB
R&S
®
ZVA67
10 MHz to 50 MHz
> 8 dB
50 MHz to 10 GHz
> 10 dB
10 GHz to 20 GHz
> 9 dB
20 GHz to 40 GHz
> 8 dB
40 GHz to 67 GHz
> 6 dB
Maximum nominal input level
R&S
®
ZVA8
300 kHz to 8 GHz
+13 dBm
R&S
®
ZVA24
10 MHz to 13 GHz
+15 dBm
13 GHz to 24 GHz
+10 dBm
R&S
®
ZVA40
10 MHz to 13 GHz
+10 dBm
13 GHz to 24 GHz
+6 dBm
24 GHz to 40 GHz
+3 dBm
R&S
®
ZVA50
10 MHz to 13 GHz
+10 dBm
13 GHz to 24 GHz
+6 dBm
24 GHz to 50 GHz
+3 dBm
R&S
®
ZVA67
10 MHz to 13 GHz
+10 dBm
13 GHz to 24 GHz
+6 dBm
24 GHz to 67 GHz
+3 dBm