Installation

25

Sensor Wiring

MoTeC can supply wiring details for all sensors.

MoTeC Supplied Wiring Loom

MoTeC can supply either partial or complete wiring looms to suit each
application.

Custom Wiring Loom

If creating a custom wiring loom the following important points should be
observed.

Connector

The ADL uses a 79 pin Auto Sport connector, see Appendix M: Connector for
full details.

To ensure that the connector is sealed plug unused holes with filler plugs. A
heat shrink boot may also be used if desired.

Crimp Tool

The correct mil spec crimping tool must be used for the ADL crimp pins. See
Appendix M: Connector for details.

• Note that the Crimp Contacts are type 22D which is needed to set the

crimp tool correctly.

CAN Bus and CAN Cable Wiring

Refer to Appendix G: CAN Wiring - Multiple Device and or Appendix H: CAN
Wiring - Single Device
for details.

External Buttons

A number of external buttons are required for various functions of the ADL.

Typically these buttons are used for:

• Display