MoTeC ADL EDL User Manual

Page 59

Advertising
background image

MoTeC

Appendices

57

Maximum : 32 msec

Pulse Width 100 usec

Measures pulse high time

Resolution : 100 usec

Maximum : 3.2 sec

Speed Input Modes

HALL Mode

Suitable for switch to 0V, Logic signal or open collector device (eg Hall
Switch)

Pullup Resistor : 4700 ohms to 5V

Voltage Range : 0 to 15V

Positive Trigger Threshold : 3.0 V max

Negative Threshold : 2.8 V min

Hysteresis : 0.19 V Min

MAGNETIC Mode

Suitable for : Two wire magnetic sensor (Variable reluctance sensor)

Input Resistance : 100k ohms to ground (No Pullup)

Voltage Range : -100V to +100V

Programmable trigger levels, variable with channel value as follows :

Selected
Level

Hi Trigger Level
( Volts ) max

Lo Trigger Level
( Volts ) min

Hysteresis
( Volts ) min

0.2 0.00

-

0.21

0.19

0.3 0.30

0.09

0.19

1.5 1.46

1.25

0.19

3.0 3.01

2.79

0.19

4.8 4.77

4.55

0.19

Advertising