Maximum resolution, Time base, Maximum resolution time base – ALLIED Vision Technologies Guppy F-503 User Manual

Page 262: Table 115: advanced register: timebase

Advertising
background image

Configuration of the camera

GUPPY Technical Manual V7.1.0

262

Maximum resolution

This register indicates the highest resolution for the sensor and is read-only.

Time base

Corresponding to IIDC, exposure time is set via a 12-bit value in the corre-
sponding register (SHUTTER_INQ [51Ch] and SHUTTER [81Ch]).

This means that a value in the range of 1 to 4095 can be entered.

Guppy cameras use a time base which is multiplied by the shutter register
value. This multiplier is configured as the time base via the TIMEBASE regis-
ter.

The time base IDs 0-9 are in bits 28 to 31. See

Table 116: Time base ID

on

page 263. Refer to the following table for code.

Default time base is 20 µs: This means that the integration time can be
changed in 20 µs increments with the shutter control.

Note

This register normally outputs the MAX_IMAGE_SIZE_INQ
Format_7 Mode_0 value.

This is the value given in the specifications tables under
Picture size (max.) in Chapter

Specifications

on page 29.

Register

Name

Field

Bit

Description

0xF1000200

MAX_RESOLUTION

MaxHeight

[0..15]

Sensor height
(read only)

MaxWidth

[16..31]

Sensor width
(read only)

Table 114: Advanced register: Max. resolution inquiry

Register

Name

Field

Bit

Description

0xF1000208

TIMEBASE

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..7]

Reserved

ExpOffset

[8..19]

Exposure offset in µs

---

[20..27] Reserved

Timebase_ID

[28..31] See

Table 116: Time base ID

on page 263.

Table 115: Advanced register: Timebase