Error codes, Reset of error codes, Error codes reset of error codes – ALLIED Vision Technologies Guppy F-503 User Manual

Page 278

Advertising
background image

Configuration of the camera

GUPPY Technical Manual V7.1.0

278

Store

To store the current camera settings into a profile:

1.

Write the desired ProfileID with the SaveProfile flag set

2.

Read back the register and check the ErrorCode field

Restore

To restore the settings from a previous stored profile:

1.

Write the desired ProfileID with the RestoreProfile flag set

2.

Read back the register and check the ErrorCode field

Set default

To set the default profile to be loaded on startup, reset or initialization:

1.

Write the desired ProfileID with the SetDefaultID flag set

2.

Read back the register and check the ErrorCode field

To go back to the factory default profile:

1.

Select ProfileID= 0 and toggle the SetDefaultID flag set

2.

Read back the register and check the ErrorCode field

Error codes

Reset of error codes

The ErrorCode field is set to zero on the next write access.

You may also reset the ErrorCode

by writing to the USER_PROFILE register with the SaveProfile,
RestoreProfile and SetDefaultID flag not set.

by writing 00000000h to the USER_PROFILE register.

ErrorCode #

Description

0x00

No error

0x01

Profile data corrupted

0x02

Camera not idle during restore operation

0x03

Feature not available (feature not present)

0x04

Profile does not exist

0x05

ProfileID out of range

0x06

Restoring the default profile failed

0x07

Loading LUT data failed

0x08

Storing LUT data failed

Table 129: User profile: Error codes