Auto shutter control, Table, Advanced register: auto shutter control – ALLIED Vision Technologies Guppy F-503 User Manual

Page 271: Table 121: advanced register: delayed integration, Enable (intena), Table 122: advanced register: auto shutter control

Advertising
background image

Configuration of the camera

GUPPY Technical Manual V7.1.0

271

Auto shutter control

The table below illustrates the advanced register for auto shutter control.
The purpose of this register is to limit the range within which auto shutter
operates.

When both auto shutter and auto gain are enabled, priority is given to
increasing shutter when brightness decreases. This is done to achieve the
best image quality with lowest noise.

For increasing brightness, priority is given to lowering gain first for the same
purpose.

Register

Name

Field

Bit

Description

0xF1000340 IO_INTENA_DELAY

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..5]

Reserved

ON_OFF

[6]

Enable/disable integration
enable delay

---

[7..11]

Reserved

DELAY_TIME

[12..31]

Delay time in µs

Table 121: Advanced register: Delayed Integration Enable (IntEna)

Register

Name

Field

Bit

Description

0xF1000360 AUTOSHUTTER_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..31]

Reserved

0xF1000364 AUTOSHUTTER_LO

---

[0..5]

Reserved

MinValue

[6..31]

Minimum auto shutter value

0xF1000368 AUTOSHUTTER_HI

---

[0..5]

Reserved

MaxValue

[6..31]

Maximum auto shutter value

Table 122: Advanced register: Auto shutter control

Note

Values can only be changed within the limits of shutter
CSR.

Changes in auto exposure register only have an effect
when auto shutter is enabled.

Auto exposure limits are: 50..205 (SmartViewCtrl1
tab
: Target grey level)

Advertising
This manual is related to the following products: