3.3 Main parts

1. Safety box:

Mounted on the gas block to ensure and check ignition
sequences, plus burner operation and extinguishing sequences.

2. Gas regulation block:

It has a progressive opening, regulation valve and safety valve in
series which is controlled by the boiler adjustment dial.

3. Gas inlet

4. Burner

5. Flame inspection window

6. Ignition electrode:

This ensures ignition burner ignition using a high voltage spark.

7. Ionization probe:

This detects the presence of a burner ignition flame through
ionization.

8. Ignition burner

9. Ignition burner gas supply pipe

10. Downdraught thermostat (located on the rear wall of the anti-

blowback device)
In the event of smoke release, the burner is cut and the boiler
goes into standby for 15 minutes. It must not be switched off or
moved at any time.The boiler restarts normally after this
thermostat has cooled and the 15 minutes has finished (indicated
by an alarm indicator flashing on the control panel).